Although most of our tanks are successfully delivered to the European market, UL Listed certification allows us to operate as a global partner. An Italian manufacturer with an official North American certification offers customers short-range supply for European projects, UL 142 tanks ready for installation in the United States, underground tanks also certified for Canada, and the manufacturing flexibility of Made in Italy.

UL standard: the requirements and how we meet them

The UL standard sets very strict requirements focused on the total prevention of environmental and fire risks. To comply with UL regulations, our production follows rigorous parameters that include:

  • Material quality and traceability: Exclusive use of certified structural steels with strictly regulated minimum thicknesses.
  • Qualified welding processes: Welding procedures performed by qualified personnel according to UL approved specifications, to ensure perfect structural integrity over time.
  • Geometries and tolerances: Precise compliance with the construction tolerances and containment volumes required by the standard for all types of tanks.

UL certification: how it is obtained and periodic inspections

UL certification, also referred to as UL approval, is not a goal that is reached once and for all, but a continuous quality journey.

  • Obtaining it: It requires a complex engineering phase and the initial validation of the prototypes by the technicians of UL Solutions (formerly Underwriters Laboratories), who test the mechanical and structural strength of the tanks.
  • Periodic inspections: Once certified, UL carries out periodic, unannounced inspections directly inside our production plants. The inspectors check material records, instrument calibrations and the consistency of quality processes. This rigorous control means that UL guarantees over time that the supplier keeps meeting the high standards required.

UL marking: the final step

Many companies claim to build "in compliance with UL standards" or to use certified components, but very few achieve the actual UL Marking (UL Listed) on the finished product.

  • Standard vs Marking: Complying with the standard is a design choice made by the manufacturer; obtaining the Marking means that the third-party body has verified the entire process and authorizes the application of the official plate on the tank.
  • What it means for the European and international market: The UL marking applied to the tank is the tool that gives the customer complete certainty that the required UL standard has been met. It is essential both for companies in Europe that must pass international audits and for those exporting to North America, where the physical plate on the tank is the only legal element that allows the system to be connected without disputes.
  • How we apply the marking: As authorized UL Listed manufacturers, we apply the official marking directly on the tank at the end of our production cycle. Each unit is tested in-house through our testing protocol and the Leak Tightness Test (high-precision pneumatic tightness test), ensuring that every tank leaving our factory with the UL plate strictly complies with the quality standards and the unique serial number approved by UL.

Verify our UL certification

Our certifications are public and can be verified on Product iQ, the official UL Solutions database:

  • Aboveground Flammable-liquid Tanks (UL 142): category EEEV, file MH67715.
  • Underground Tanks: category EGHX, file MH68631.
  • Underground Tanks Certified for Canada: category EGHX7, file MH68631.
UL Certified nameplate on an aboveground tank for flammable liquids with secondary containment
The UL Certified nameplate applied at the factory on one of our aboveground tanks with secondary containment.

UL 142 tanks

What the UL 142 standard is

The UL 142 standard (Steel Aboveground Tanks for Flammable and Combustible Liquids) is the international reference standard that specifically governs the design, manufacture and testing of aboveground steel tanks intended for the storage of flammable and combustible liquids at atmospheric pressure.

We manufacture UL 142 tanks in both cylindrical and rectangular shapes, with single or double walls. We combine the strictness of American safety standards with the typical flexibility of Italian manufacturing: we customize each tank according to the required layout, with a build quality and attention to detail superior to the standardized products found overseas.

Why it is required in Europe and the United States

  • The reference point in Europe for large specifications: In the European market the UL 142 standard is not an optional choice, but a technical pillar increasingly required in the specifications of multinationals and large engineering companies (EPC). When a large international group (such as a chemical, pharmaceutical or IT giant) designs a new plant or a Data Center in Europe, it imposes the global standardization of its systems. This means that fuel storage systems must be identical in every branch around the world, aligning safety and internal maintenance procedures on a single recognized standard: UL 142. These organizations demand uniform safety levels worldwide, often tied to strict international insurance requirements.
  • Regulatory requirement in the United States: Overseas, compliance with the UL 142 standard is an essential legal requirement built into national safety codes. Without this certification, the installation and commissioning of aboveground tanks are prohibited by local authorities.

Applications of UL 142 tanks

Our UL 142 aboveground tanks are used in critical industrial settings where continuity of service and safety are vital:

  • Oil & Gas and petroleum sector: Storage of fuels, hydrocarbons and process fluids in refineries and depots.
  • Power Generation (generator sets): Service and main storage tanks for the continuity and backup power systems of Data Centers, hospitals and large infrastructure.
  • Chemical and industrial plants: Handling of combustible liquids used in automated production processes.

Export of UL 142 tanks

  • For European construction sites: For companies and multinationals operating in Europe, buying a UL certified tank directly in Italy removes transatlantic shipping costs and long waiting times. Our presence in Italy ensures a short supply chain, fast road shipments and no customs complications, for a product with the highest legal and technical validity and delivery times kept to a minimum. We are the ideal short-range partner for all European projects with international technical specifications.
  • For export to the United States: The UL 142 marking plate applied directly at the factory guarantees no paperwork obstacles, priority clearance and extremely simplified customs procedures at US ports of arrival. The tank reaches its destination legally and technically ready to be connected: this eliminates site stoppages and costly additional on-site inspections, and ensures immediate approval by local inspectors (AHJ - Authorities Having Jurisdiction) and American insurance companies.

Benefits of certification for the customer

  • No risk of disputes: Absolute certainty that the tank will be approved by European control bodies and by local American inspectors (AHJ).
  • Global insurance compliance: Full facilitation of the paperwork and lower international insurance coverage costs for the entire industrial plant.
  • Superior reliability: The guarantee that the tank was built following some of the strictest metallurgical and welding controls in the world.
  • Environmental sustainability: Total protection against the risk of hydrocarbon leaks thanks to certified containment systems.